Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1" NPT Direction 2/2 Way Body Material Brass Sealing Material FKM (fluoroelastomer) Flow 190.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 3/4" NPT Direction 2/2 Way Body Material Brass Sealing Material FKM (fluoroelastomer) Flow 140.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 3/4" NPT Direction 2/2 Way Body Material Brass Sealing Material EPDM (ethylene-propylene) Flow 140.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 3/4" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 140.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/8" NPT Direction 2/2 Way Body Material Stainless Steel 316 Sealing Material PTFE (polytetrafluorethylene) Flow 3.2 L/min Pressure Rating 0-30 bar (0-435 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Proportional Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/8" BSP Direction 2/2 Way Body Material Plastic - PPS Sealing Material FKM (Fluoroelastomer) Flow 1.1 L/min Pressure Rating 0-10 bar (0 - 145 psi) Certifications CSA, UL, CRN, NSF Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Combined Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Low Lead Brass Sealing Material RUBY Flow 3.2 L/min Pressure Rating 0-14 bar (0-203 psi) Certifications CSA, UL, CRN, NSF Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/8" BSP Direction 2/2 Way Body Material Low Lead Brass Sealing Material FKM (Fluoroelastomer) Flow 3.2 L/min Pressure Rating 0-14 bar (0 - 203 psi) Certifications CSA, UL, CRN, NSF Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/2" NPT Direction 2/2 Way Body Material Nickel-Plated Brass Sealing Material EPDM (ethylene-propylene) Flow 70.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/2" NPT Direction 2/2 Way Body Material Nickel-Plated Brass Sealing Material H-NBR (hydrogenated nitrile) Flow 70.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/2" NPT Direction 2/2 Way Body Material Nickel-Plated Brass Sealing Material NBR (Nitrile Rubber) Flow 70.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/2" NPT Direction 2/2 Way Body Material Nickel-Plated Brass Sealing Material FKM (Fluoroelastomer) Flow 70.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/2" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 70.0 L/min Pressure Rating 0.2-16 bar (3 -232 psi) Certifications CSA, UL, CRN Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/2" BSP Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 70.0 L/min Pressure Rating 0.1-20 bar (1.5 - 290 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Proportional Direct Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/4" BSP Direction 2/2 Way Body Material Brass Sealing Material FKM (Fluoroelastomer) Flow 4 L/min Pressure Rating 0-5 bar (0 - 72 psi) Certifications CSA, UL, CRN, NSF Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/4" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 4 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/4" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 3.2 L/min Pressure Rating 0-14 bar (0-203 psi) Certifications CSA, UL, CRN, , ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/4" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 2.0 L/min Pressure Rating 0-22 bar (0-319 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/4" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 1.4 L/min Pressure Rating 0-30 bar (0-435 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/4" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 4 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 3.2 L/min Pressure Rating 0-14 Bar (0-203 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/4" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 2.0 L/min Pressure Rating 0-22 bar (0-319 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/4" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 1.4 L/min Pressure Rating 0-30 bar (0-435 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 4 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.