Looking for ASCO, Burkert, GC, Jefferson, or Parker solenoid valve replacements? Switch to ODE—we've got you covered. Get in touch with us at contact@hydronicsdepotinc.com or call 1-800-936-2819.
Looking for ASCO, Burkert, GC, Jefferson, or Parker solenoid valve replacements? Switch to ODE—we've got you covered. Get in touch with us at contact@hydronicsdepotinc.com or call 1-800-936-2819.
Valve Function Direct Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/8" NPT Direction 2/2 Way Body Material Stainless Steel 316 Sealing Material PTFE (polytetrafluorethylene) Flow 3.2 L/min Pressure Rating 0-30 bar (0-435 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Proportional Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/8" BSP Direction 2/2 Way Body Material Plastic - PPS Sealing Material FKM (Fluoroelastomer) Flow 1.1 L/min Pressure Rating 0-10 bar (0 - 145 psi) Certifications CSA, UL, CRN, NSF Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Combined Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Low Lead Brass Sealing Material RUBY Flow 3.2 L/min Pressure Rating 0-14 bar (0-203 psi) Certifications CSA, UL, CRN, NSF Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/8" BSP Direction 2/2 Way Body Material Low Lead Brass Sealing Material FKM (Fluoroelastomer) Flow 3.2 L/min Pressure Rating 0-14 bar (0 - 203 psi) Certifications CSA, UL, CRN, NSF Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Total Separation Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Pipe 1/8" BSP Direction 3/2 Way Body Material PSU Sealing Material VMQ (Silicon) Flow 4.5 L/min Pressure Rating 0-6 bar (0-87 psi) Certifications CSA, UL, CRN Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 4.0 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOW N LOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 3.2 L/min Pressure Rating 0-14 bar (0-203 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOW N LOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 2 L/min Pressure Rating 0-20 bar (0-290 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOW N LOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 1.4 L/min Pressure Rating 0-25 bar (0-362 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 4.0 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOW N LOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 3.2 L/min Pressure Rating 0-14 bar (0-203 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOW N LOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 2 L/min Pressure Rating 0-20 bar (0-290 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOW N LOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 1.4 L/min Pressure Rating 0-25 bar (0-362 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 4 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 3.2 L/min Pressure Rating 0-14 bar (0-203 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 2.0 L/min Pressure Rating 0-22 bar (0-319 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material H-NBR (hydrogenated nitrile) Flow 1.4 L/min Pressure Rating 0-30 bar (0-435 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 4 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 3.2 L/min Pressure Rating 0-14 bar (0-203 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 2.0 L/min Pressure Rating 0-22 bar (0-319 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Explosion Proof- ATEX Ex d Solenoid Valve Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/8" BSP Direction 2/2 Way Body Material Stainless Steel Sealing Material FKM (Fluoroelastomer) Flow 1.4 L/min Pressure Rating 0-30 bar (0-435 psi) Certifications CSA, UL, CRN, ATEX Data Sheet DOWNLOAD Instruction Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/8" BSP Direction 3/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 2.3 L/min Pressure Rating 0-5 bar (0-72 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/8" BSP Direction 3/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 1.0 L/min Pressure Rating 0-15 bar (0-217 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/8" BSP Direction 2/2 Way Body Material Low Lead Brass Sealing Material FKM (Fluoroelastomer) Flow 6.5 L/min Pressure Rating 0-5 bar (0 - 72 psi) Certifications CSA, UL, CRN, NSF Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.