Valve Function Direct Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/4" BSP Direction 2/2 Way Body Material Brass Sealing Material FKM (Fluoroelastomer) Flow 0.45 L/min Pressure Rating 0-35 bar (0 - 507 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Subplate Direction 3/2 Way Body Material Brass Sealing Material FKM (Fluoroelastomer) Flow 1.0 L/min Pressure Rating 0-15 bar (0-217 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 150.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 3/4" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 120.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/2" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 35.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 2" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 750.0 L/min Pressure Rating 0.2-10 bar (3-145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1-1/2" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 520.0 L/min Pressure Rating 0.2-10 bar (3-145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1" NPT Direction 2/2 Way Body Material Brass Sealing Material FKM (Fluoroelastomer) Flow 190.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 3/4" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 140.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1-1/2" NPT Direction 2/2 Way Body Material Low Lead Brass Sealing Material FKM (Fluoroelastomer) Flow 520.0 L/min Pressure Rating 0.2-10 bar (3-145 psi) Certifications CSA, UL, CRN, NSF Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1-1/4" NPT Direction 2/2 Way Body Material Low Lead Brass Sealing Material FKM (Fluoroelastomer) Flow 400.0 L/min Pressure Rating 0.2-10 bar (3-145 psi) Certifications CSA, UL, CRN, NSF Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1" NPT Direction 2/2 Way Body Material Low Lead Brass Sealing Material EPDM (ethylene-propylene) Flow 190.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN, NSF Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 3/4" NPT Direction 2/2 Way Body Material Brass Sealing Material EPDM (ethylene-propylene) Flow 140 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN, NSF Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1" NPT Direction 2/2 Way Body Material Low Lead Brass Sealing Material EPDM (ethylene-propylene) Flow 190.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN, NSF Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 3/4" NPT Direction 2/2 Way Body Material Low Lead Brass Sealing Material EPDM (ethylene-propylene) Flow 140.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN, NSF Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/2" NPT Direction 2/2 Way Body Material Low Lead Brass Sealing Material EPDM (ethylene-propylene) Flow 70.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN, NSF Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/2" BSP Direction 2/2 Way Body Material Brass Sealing Material PTFE (polytetrafluorethylene) Flow 38.0 L/min Pressure Rating 0.5-20 bar (7.3-290 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 3/8" BSP Direction 2/2 Way Body Material Brass Sealing Material PTFE (polytetrafluorethylene) Flow 32.0 L/min Pressure Rating 0.5-20 bar (7.3-290 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material FKM (Fluoroelastomer) Flow 160.0 L/min Pressure Rating 0.1-16 bar (1.5 - 232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/2" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material FKM ( Fluoroelastomer) Flow 35.0 L/min Pressure Rating 0.1-20 bar (1.5 - 290 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1" BSP Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material PTFE (polytetrafluorethylene) Flow 130.0 L/min Pressure Rating 0.5-10 bar (7.3 -145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1/2" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 70.0 L/min Pressure Rating 0.2-12 bar (3-174 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 3/8" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 60.0 L/min Pressure Rating 0.2-12 bar (3-174 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/2" BSP Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 70.0 L/min Pressure Rating 0.2-12 bar (3 - 174 PSI) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.