Looking for ASCO, Burkert, GC, Jefferson, or Parker solenoid valve replacements? Switch to ODE—we've got you covered. Get in touch with us at contact@hydronicsdepotinc.com or call 1-800-936-2819.
Looking for ASCO, Burkert, GC, Jefferson, or Parker solenoid valve replacements? Switch to ODE—we've got you covered. Get in touch with us at contact@hydronicsdepotinc.com or call 1-800-936-2819.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 2" BSP Direction 2/2 Way Body Material Brass Sealing Material NBR ( Nitrile Rubber) Flow 750.0 L/min Pressure Rating 0.2-10 bar (3 - 145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1-1/2" BSP Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 520.0 L/min Pressure Rating 0.2-10 bar (3 - 145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1-1/4" BSP Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 400.0 L/min Pressure Rating 0.2-10 bar (3 - 145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1" BSP Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 190.0 L/min Pressure Rating 0.2-16 bar (3 - 232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 3/4" BSP Direction 2/2 Way Body Material Brass Sealing Material NBR (Nitrile Rubber) Flow 140.0 L/min Pressure Rating 0.2-16 bar (3 - 232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 2" NPT Direction 2/2 Way Body Material Nickel-Plated Brass Sealing Material NBR (Nitrile Rubber) Flow 750.0 L/min Pressure Rating 0.2-10 bar (3-145 psi) Certifications CSA, UL, CRN Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
bValve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1-1/2" NPT Direction 2/2 Way Body Material Nickel-Plated Brass Sealing Material NBR (Nitrile Rubber) Flow 520.0 L/min Pressure Rating 0.2-10 bar (3-145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 1-1/4" NPT Direction 2/2 Way Body Material Nickel-Plated Brass Sealing Material NBR (Nitrile Rubber) Flow 400.0 L/min Pressure Rating 0.2-10 bar (3-145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe Size 1" NPT Direction 2/2 Way Body Material Nickel-Plated Brass Sealing Material NBR (Nitrile Rubber) Flow 190.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe Size 3/4" NPT Direction 2/2 Way Body Material Nickel-Plated Bras Sealing Material NBR (Nitrile Rubber) Flow 140.0 L/min Pressure Rating 0.2-16 bar (3-232 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Type Angle Seat Valve Actuation Pneumatic Operated Flow Direction Below Seat Valve Starting Position Normally Closed Pipe 2" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material PTFE (Teflon) Flow 620.0 L/min Pressure Rating 0-3 bar (0-43 psi) Certifications CE Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Type Angle Seat Valve Actuation Pneumatic Operated Flow Direction Below Seat Valve Starting Position Normally Closed Pipe 1-1/2" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material PTFE (Teflon) Flow 430.0 L/min Pressure Rating 0-4.5 bar (0-65 psi) Certifications CE Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Type Angle Seat Valve Actuation Pneumatically Operated Flow Direction Below Seat Valve Starting Position Normally Closed Pipe 1/2" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material PTFE (Teflon) Flow 80.0 L/min Pressure Rating 0-16 bar (0-232 psi) Certifications CE Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Combined Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 3/4" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material FKM+ PA (Fluoroelastomer + Polyamide) Flow 50.0 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Combined Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 1/2" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material FKM+ PA (Fluoroelastomer + Polyamide) Flow 40.0 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Combined Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 3/8" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material FKM+ PA (Fluoroelastomer + Polyamide) Flow 30.0 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Combined Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 3/4" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR+PA (Nitrile Rubber + Polyamide) Flow 40.0 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Combined Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 1/2" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR+PA (Nitrile Rubber + Polyamide) Flow 40.0 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Combined Acting Valve Type General Purpose Solenoid Valve Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 3/8" NPT Direction 2/2 Way Body Material Brass Sealing Material NBR+PA (Nitrile Rubber + Polyamide) Flow 20.0 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CSA, UL, CRN Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Type Angle Seat Valve Actuation Pneumatically Operated Flow Direction Below Seat Valve Starting Position Normally Closed Pipe 2" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material PTFE Flow 660.0 L/min Pressure Rating 0-10 bar (0-145 psi) Certifications CE Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Type Angle Seat Valve Actuation Pneumatically Operated Flow Direction Below Seat Valve Starting Position Normally Closed Pipe 1-1/2" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material PTFE Flow 411.0 L/min Pressure Rating 0-16 bar (0-232 psi) Certifications CE Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Type Angle Seat Valve Actuation Pneumatically Operated Flow Direction Below Seat Valve Starting Position Normally Closed Pipe 1-1/4" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material PTFE Flow 289.0 L/min Pressure Rating 0-16 bar (0-232 psi) Certifications CE Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Type Angle Seat Valve Actuation Pneumatically Operated Flow Direction Below Seat Valve Starting Position Normally Closed Pipe 1-1/2" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material PTFE Flow 411.0 L/min Pressure Rating 0-5 bar (0-72 psi) Certifications CE Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Type Angle Seat Valve Actuation Electric (Solenoid) Flow Direction Below Seat Valve Starting Position Normally Closed Pipe 1-1/4" NPT Direction 2/2 Way Body Material Stainless Steel - SS316 Sealing Material PTFE Flow 289.0 L/min Pressure Rating 0-6 bar (0-87 psi) Certifications CE Data Sheet ⇲ DOWNLOAD ⚠ 3D Drawings are available upon request.