Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 2-1/2" Direction 2/2 Way Body Material Cast Iron Sealing Material NBR Flow Coefficient (Cv) 68 gpm Pressure Rating 0.5-8 bar (7.3-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 2" Direction 2/2 Way Body Material Cast Iron Sealing Material NBR Flow Coefficient (Cv) 40 gpm Pressure Rating 0.5-8 bar (7.3-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1-1/2" Direction 2/2 Way Body Material Cast Iron Sealing Material NBR Flow Coefficient (Cv) 30 gpm Pressure Rating 0.5-8 bar (7.3-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 1-1/2" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 30 gpm Pressure Rating 1-8 bar (14.5-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 4" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 175 gpm Pressure Rating 1-8 bar (14.5-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 3" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 100 gpm Pressure Rating 1-8 bar (14.5-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 2-1/2" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 68 gpm Pressure Rating 1-8 bar (14.5-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 2" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 40 gpm Pressure Rating 1-8 bar (14.5-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 4" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 175 gpm Pressure Rating 1-10 bar (14.5-145 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 3" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 100 gpm Pressure Rating 1-10 bar (14.5-145 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 2-1/2" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 68 gpm Pressure Rating 1-10 bar (14.5-145 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 2" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 40 gpm Pressure Rating 1-10 bar (14.5-145 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1-1/2" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 30 gpm Pressure Rating 1-10 bar (14.5-145 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 1-1/4" Direction 2/2 Way Body Material Cast Iron Sealing Material NBR Flow Coefficient (Cv) 22 gpm Pressure Rating 0.5-8 bar (7.3-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1-1/4" Direction 2/2 Way Body Material Cast Iron Sealing Material NBR Flow Coefficient (Cv) 22 gpm Pressure Rating 0.5-8 bar (7.3-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Open Pipe 1-1/4" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 22 gpm Pressure Rating 1-8 bar (14.5-116 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Indirect Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1-1/4" Direction 2/2 Way Body Material Cast Iron Sealing Material PTFE Flow Coefficient (Cv) 22 gpm Pressure Rating 1-10 bar (14.5-145 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1-1/2" Direction 2/2 Way Body Material Forged Brass Sealing Material NBR Flow Coefficient (Cv) 48 gpm Pressure Rating 0-7 bar (0-101 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1-1/2" Direction 2/2 Way Body Material Forged Brass Sealing Material NBR Flow Coefficient (Cv) 28 gpm Pressure Rating 0-7 bar (0-101 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1-1/4" Direction 2/2 Way Body Material Forged Brass Sealing Material NBR Flow Coefficient (Cv) 24 gpm Pressure Rating 0-7 bar (0-101 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1" Direction 2/2 Way Body Material Forged Brass Sealing Material NBR Flow Coefficient (Cv) 12 gpm Pressure Rating 0-7 bar (0-101 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 3/4" Direction 2/2 Way Body Material Forged Brass Sealing Material NBR Flow Coefficient (Cv) 8.6 gpm Pressure Rating 0-7 bar (0-101 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 1/2" Direction 2/2 Way Body Material Forged Brass Sealing Material NBR Flow Coefficient (Cv) 4.5 gpm Pressure Rating 0-7 bar (0-101 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.
Valve Function Direct Acting Valve Type General Purpose Fitting Type Connector Actuation Electric (Solenoid) Valve Starting Position Normally Closed Pipe 3/8" Direction 2/2 Way Body Material Forged Brass Sealing Material NBR Flow Coefficient (Cv) 2.4 gpm Pressure Rating 0-7 bar (0-101 psi) Certifications CSA, UL, CE Data Sheet DOWNLOAD ⚠ 3D Drawings are available upon request.